Thank you for choosing to partner with National Stock Number Shop for the Transformer Power NSN parts you require. On this page, you can submit a quote request for Wems Electronics part number WE-3996, a component that can also be found by inputting NSN 5950013173101 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 26543 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Wems Electronics parts under the FSC 5950 Coils and Transformers with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 5950013173101 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-317-3101 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013173101 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
WE-3996 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.308 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.328 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.365 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.385 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.271 INCHES MINIMUM SINGLE GROUP AND 0.276 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.600 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.775 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.035 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 6 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT AND 1 TERTIARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 198.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.05 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE TERTIARY |
CRBZ | WINDING OPERATING CURRENT | 2.2 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 353.5 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.43 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 1.79 KILOVOLT-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 116.38 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 28.13 VOLTS-AMPERES SINGLE COMPONENT SINGLE TERTIARY |
CRMJ | WINDING POWER RATING | 3.2 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 59.73 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 13.72 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE TERTIARY |
CWJS | WINDING OPERATING VOLTAGE | 18.10 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 226.24 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 27.15 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 9.05 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 9.05 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; SIX SECONDARY WINDINGS; TERMINALS 23 AND 24 SPLIT FOR DUAL CONNECTION; TERTIARY WINDING TIED TO THE FOURTH SECONDARY WINDING |
TEST | TEST DATA DOCUMENT | 82577-H940081 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 1 BUS (BAR) CONDUCTOR AND 22 PIN AND 2 RIBBON |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote