Thank you for choosing to partner with National Stock Number Shop for the Circuitbreaker NSN parts you require. On this page, you can submit a quote request for Sensata Technologies Inc part number PP11-1-0.500A-0B-V, a component that can also be found by inputting NSN 5925015756956 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 82647 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Sensata Technologies Inc parts under the FSC 5925 Circuit Breakers with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 5925015756956 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-575-6956 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015756956 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
PP11-1-0.500A-0B-V | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CXCY | Part Name Assigned By Controlling Agency | CAGE: SNAPAK SERIES MAGNETIC CIRCUIT PROTECTOR |
AKPX | Pole Quantity | 1 |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 SINGLE LOCATION |
ADAT | Body Width | 1.304 INCHES NOMINAL |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
AXHR | Mounting Facility Type And Quantity | 4 TERMINAL |
AGAV | End Item Identification | C-10256C/BRR-6 TRIDENT, CONTROL INDICATOR; C-10256D/BRR-6 TRIDENT, CONTROL INDICATOR; OHIO CLASS SSBN |
ADTV | Case Material | PLASTIC |
TTQY | Terminal Type And Quantity | 4 KNIFE BLADE |
MRC | Decoded Requirement | Clear Text Reply |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
ABHP | Overall Length | 1.375 NOMINAL INCHES |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 DC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 1.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 8.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote