Thank you for choosing to partner with National Stock Number Shop for the Circuit Breaker NSN parts you require. On this page, you can submit a quote request for Sensata Technologies Inc part number IULHK1119-1REC4-30372-21, a component that can also be found by inputting NSN 5925015017437 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 81541 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Sensata Technologies Inc parts under the FSC 5925 Circuit Breakers with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 5925015017437 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-501-7437 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015017437 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
IULHK1119-1REC4-30372-21 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.250 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 35.0 AMPERES AC FIRST LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 35.0 AMPERES AC SECOND LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 35.0 AMPERES AC THIRD LOCATION |
AKPX | Pole Quantity | 4 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC THIRD LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC FIRST LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 28.0 DC FOURTH LOCATION |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | 70.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AJEC | Boss Height | 1.042 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
AXHR | Mounting Facility Type And Quantity | 6 THREADED STUD |
ADAT | Body Width | 2.490 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.138 INCHES |
AGAV | End Item Identification | 5895-01-467-7213 |
ADTV | Case Material | METAL |
AAQL | Body Style | |
FEAT | Special Features | 1ST POLE HAS SINGLE POLE DOUBLE THROW AUXILIARY SWITCH |
AJWX | Mounting Surface To Terminal End Distance | 2.529 INCHES NOMINAL |
ADAQ | Body Length | 3.015 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 120.0 MILLIAMPERES DC FOURTH LOCATION |
MRC | Decoded Requirement | Clear Text Reply |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SECOND LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT FIRST LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.000 NOMINAL AT 125 PCT FOURTH LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT SECOND LOCATION |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT THIRD LOCATION |
THSD | Thread Series Designator | UNC |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.