Thank you for choosing to partner with National Stock Number Shop for the Circuitbreaker NSN parts you require. On this page, you can submit a quote request for Sensata Technologies Inc part number AP1-1RC-50-502, a component that can also be found by inputting NSN 5925013418164 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 81541 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Sensata Technologies Inc parts under the FSC 5925 Circuit Breakers with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 5925013418164 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-341-8164 Item PartTypeName: CIRCUIT BREAKER | 5925 | 013418164 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AP1-1RC-50-502 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ADAT | BODY WIDTH | 0.625 INCHES MAXIMUM |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 DC SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNEF |
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0.380 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.605 INCHES MAXIMUM |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK |
ADAQ | BODY LENGTH | 1.562 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.875 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 SINGLE LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.010 MINIMUM AT 150 PCT AND 0.035 MAXIMUM AT 150 PCT SINGLE LOCATION |