Thank you for choosing to partner with National Stock Number Shop for the Circuit Breaker NSN parts you require. On this page, you can submit a quote request for Schneider Electric Gmbh part number C60HC106, a component that can also be found by inputting NSN 5925016145148 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 56365 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Schneider Electric Gmbh parts under the FSC 5925 Circuit Breakers with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 5925016145148 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-614-5148 Item PartTypeName: CIRCUIT BREAKER | 5925 | 016145148 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
C60HC106 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAQ | BODY LENGTH | 81.0 MILLIMETERS NOMINAL |
ADAU | BODY HEIGHT | 18.0 MILLIMETERS NOMINAL |
AGAV | END ITEM IDENTIFICATION | RAM WARNING S |
AKPX | POLE QUANTITY | 1 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 6.0 AMPERES AC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC FIRST LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 10.0 ALL LOCATIONS |
CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS ALL LOCATIONS |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | MINATURE CIRCUIT BREAKER, 6A, 1 POLE, TYPE C |
FEAT | SPECIAL FEATURES | TRIP DELAY IS 1/10 OF A SECOND; EXTERNAL DEPTH IS 70MM; VOLTAGE INSULATION IS 415 VOLTZ; MOUNTING TYPE IS DIN RAIL |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.