Thank you for choosing to partner with National Stock Number Shop for the Transformer Current NSN parts you require. On this page, you can submit a quote request for Raytheon Company part number MT4184, a component that can also be found by inputting NSN 5950013450204 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 37695 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Raytheon Company parts under the FSC 5950 Coils and Transformers with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 5950013450204 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-345-0204 Item PartTypeName: TRANSFORMER,CURRENT | 5950 | 013450204 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
305254-1 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 1.320 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.870 INCHES MAXIMUM |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 28.50 DC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 34.00 DC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TEST | TEST DATA DOCUMENT | 37695-305254 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
ABHP | OVERALL LENGTH | 3.130 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.140 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.880 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES DC MINIMUM SINGLE COMPONENT SINGLE SECONDARY AND 15.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
FEAT | SPECIAL FEATURES | SECONDARY WINDING TERMINALS 4,5,AND 6 ARE SPLIT FOR DUAL CONNECTION |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 10 WIRE HOOK AND 1 TURRET |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |