Thank you for choosing to partner with National Stock Number Shop for the Switch Pressure NSN parts you require. On this page, you can submit a quote request for Northrop Grumman Systems Corporation part number 2JC4273H07, a component that can also be found by inputting NSN 5930001681397 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 97942 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Northrop Grumman Systems Corporation parts under the FSC 5930 Switches with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 5930001681397 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-168-1397 Item PartTypeName: SWITCH,PRESSURE | 5930 | 001681397 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2JC4273H07 | 2 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.248 INCHES NOMINAL |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.624 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.077 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | ABSOLUTE |
AWTN | OPERATING TEMP RATING | -65.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CQJB | PROOF PRESSURE | 35.00 POUNDS PER SQUARE INCH |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TURRET |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote