Thank you for choosing to partner with National Stock Number Shop for the Waveguideassembly NSN parts you require. On this page, you can submit a quote request for Microwave Engineering Corporation part number H10-2926, a component that can also be found by inputting NSN 5985016000306 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 06351 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Microwave Engineering Corporation parts under the FSC 5985 Antennas Waveguides and Related Equipment with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 5985016000306 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-600-0306 Item PartTypeName: WAVEGUIDE ASSEMBLY | 5985 | 016000306 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
H10-2926 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
THSD | Thread Series Designator | UNC ALL FLANGES ALL CONNECTION FACILITIES |
AAJD | Thread Class | 3B FIRST FLANGE SINGLE CONNECTION FACILITY |
CTCJ | Flange Style | CONTACT TYPE FIRST FLANGE |
AAGR | Cross-Sectional Shape Style | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
CQGM | Maximum Operating Pressure | 25.0 POUNDS PER SQUARE INCH GAGE |
CSQT | Flange Connecting Facility And Quantity | 8 THREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
AGAV | End Item Identification | NEXT ASSEMBLY AND USED ON 200532017 |
FLEX | Flexibility | RIGID SINGLE TUBING SEGMENT |
AAJF | Thread Direction | RIGHT-HAND ALL FLANGES ALL CONNECTION FACILITIES |
AAJD | Thread Class | 3A SECOND FLANGE SINGLE CONNECTION FACILITY |
FEAT | Special Features | FLANGE TYPE: CPR-112 1X GROOVED CONTACT W/FREE RUNNING HELICOIL INSERTS, 1X COVER W/STAINLESS STEEL CAPTIVE FASTENERS SOCKET HEAD, FLAT WASHERS AND SPLIT LOCK WASHERS; WR-112 WAVEGUIDE; 250.0KW PEAK POWER HANDLING, 1.0KW AVG. POWER HANDLING; OPERATING TEMP: -40/+52 DEG C, STORAGE TEMP: -40/+68 DEG C. |
CQJX | Nominal Thread Size | 0.164 INCHES ALL FLANGES ALL CONNECTION FACILITIES |
MATT | Material | ALUMINUM ALL TUBING SEGMENT AND FLANGE |
CTCJ | Flange Style | COVER TYPE SECOND FLANGE |
CTFD | Waveguide Length | 60.000 INCHES NOMINAL |
STYL | Style Designator | STRAIGHT TYPE |
CMLP | Thread Quantity Per Inch | 32 ALL FLANGES ALL CONNECTION FACILITIES |
AHRV | Tubing Wall Construction Style | SEAMLESS ALL TUBING SEGMENT |
AHSF | Flange Quantity | 2 |
CZKN | Specified Frequency | 7.05 GIGAHERTZ MINIMUM AND 10.00 GIGAHERTZ MAXIMUM |
AHTW | Voltage Standing Wave Ratio | 1.1 |
AHTX | Insertion Loss In Decibels | 0.29 |
MRC | Decoded Requirement | Clear Text Reply |