Thank you for choosing to partner with National Stock Number Shop for the Terminal Board NSN parts you require. On this page, you can submit a quote request for Marco Seattle Inc part number 3300-08, a component that can also be found by inputting NSN 5940015289275 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 9R803 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Marco Seattle Inc parts under the FSC 5940 Lugs Terminals and Terminal Strips with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 5940015289275 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5940-01-528-9275 Item PartTypeName: TERMINAL BOARD | 5940 | 015289275 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3300-08 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAMA | MOUNTING HOLE DIAMETER | 0.174 INCHES" |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 7500.0" |
AAQL | BODY STYLE | BARRIER TYPE" |
ABCS | TERMINAL ROW QUANTITY | 2" |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.438 INCHES" |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.420 INCHES" |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION" |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.937 INCHES" |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.420 INCHES" |
ABGN | BOARD OVERALL LENGTH | 4.250 INCHES" |
ABGP | BOARD OVERALL WIDTH | 1.125 INCHES" |
ABGQ | BOARD OVERALL HEIGHT | 0.550 INCHES" |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.550 INCHES" |
ABGS | BASE THICKNESS | 0.350 INCHES" |
AGAV | END ITEM IDENTIFICATION | MARCOM SWITCH DRAWER, MARCOM IVCS" |
AMPS | CURRENT RATING IN AMPS | 20.0" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE" |
CQCW | FEEDTHRU CONNECTION END TYPE | 857 BOTH ENDS SINGLE COMBINATION" |
CRZR | FEEDTHRU TERMINAL QUANTITY | 8 SINGLE COMBINATION" |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW" |
CWLN | TERMINAL DESIGN | FEEDTHRU" |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | SERIES 3300, 7/16 IN. CENTERS DOUBLE ROW TERMINAL BLOCK" |
FEAT | SPECIAL FEATURES | VOLTAGE: 300 VOLTS; WIRE SIZE: 16-14 AWG; SCREW TYPE: 6/32 STEEL COMBO HEAD (PHILLIP/SLOT); UL FLAME RETARDANT RATING: 94V-0" |
MATT | MATERIAL | COPPER ALLOY TERMINALS" |
MATT | MATERIAL | PLASTIC BOARD" |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS" |
AAMA | MOUNTING HOLE DIAMETER | 0.174 INCHES" |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 7500.0" |
AAQL | BODY STYLE | BARRIER TYPE" |
ABCS | TERMINAL ROW QUANTITY | 2" |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.438 INCHES" |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.420 INCHES" |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION" |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.937 INCHES" |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.420 INCHES" |
ABGN | BOARD OVERALL LENGTH | 4.250 INCHES" |
ABGP | BOARD OVERALL WIDTH | 1.125 INCHES" |
ABGQ | BOARD OVERALL HEIGHT | 0.550 INCHES" |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.550 INCHES" |
ABGS | BASE THICKNESS | 0.350 INCHES" |
AGAV | END ITEM IDENTIFICATION | MARCOM SWITCH DRAWER, MARCOM IVCS" |
AMPS | CURRENT RATING IN AMPS | 20.0" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE" |
CQCW | FEEDTHRU CONNECTION END TYPE | 857 BOTH ENDS SINGLE COMBINATION" |
CRZR | FEEDTHRU TERMINAL QUANTITY | 8 SINGLE COMBINATION" |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW" |
CWLN | TERMINAL DESIGN | FEEDTHRU" |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | SERIES 3300, 7/16 IN. CENTERS DOUBLE ROW TERMINAL BLOCK" |
FEAT | SPECIAL FEATURES | VOLTAGE: 300 VOLTS; WIRE SIZE: 16-14 AWG; SCREW TYPE: 6/32 STEEL COMBO HEAD (PHILLIP/SLOT); UL FLAME RETARDANT RATING: 94V-0" |
MATT | MATERIAL | COPPER ALLOY TERMINALS" |
MATT | MATERIAL | PLASTIC BOARD" |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS" |