Thank you for choosing to partner with National Stock Number Shop for the Powersupply NSN parts you require. On this page, you can submit a quote request for Keysight Technologies Inc part number 6236B-011-240, a component that can also be found by inputting NSN 6130012146039 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 1LQK8 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Keysight Technologies Inc parts under the FSC 6130 Converters Electrical Non Rotating with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 6130012146039 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 8.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 12.500 INCHES NOMINAL |
AMQY | INSTALLATION DESIGN | BENCH OR RACK |
APNX | INPUT VOLTAGE RATING | 8.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 250.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 20.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
CBBL | FEATURES PROVIDED | ON-OFF SWITCH-INDICATOR AND DC AMMETER AND DC VOLTMETER AND OVER VOLTAGE PROTECTOR AND OVER CURRENT PROTECTOR |
CWGH | OUTPUT CURRENT RATING | 0.5 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 2ND POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 1.2 AC AMPERES NOMINAL SINGLE OPERATING POWER RQMT |
ABKW | OVERALL HEIGHT | 3.500 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
ASCX | LOAD TYPE | RESISTIVE 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | BINDING POST 3RD POWER OUTPUT |
FEAT | SPECIAL FEATURES | ONE 2OV OUTPUT IS NEGATIVE; 0 TO 20 V OUTPUTS TRACK; TRACKING RATIO CONTROL |