Thank you for choosing to partner with National Stock Number Shop for the Transformer Power NSN parts you require. On this page, you can submit a quote request for Harris Corporation part number 160007-1, a component that can also be found by inputting NSN 5950001408156 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 24930 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Harris Corporation parts under the FSC 5950 Coils and Transformers with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 5950001408156 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-140-8156 Item PartTypeName: TRANSFORMER,POWER | 5950 | 001408156 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | 0 | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
160007-1 | C | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 8.970 INCHES MINIMUM AND 9.030 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 7.030 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 7.970 INCHES MINIMUM AND 8.030 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.358 INCHES MINIMUM ALL GROUPINGS AND 0.366 INCHES MAXIMUM ALL GROUPINGS |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT AND CORE GROUNDED TO SECONDARY TERMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 7.970 INCHES MINIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS AND 8.030 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 3 ALL GROUPINGS |
AXGY | MOUNTING METHOD | UNTHREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.25 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY |
CRMJ | WINDING POWER RATING | 2.125 KILOVOLT-AMPERES SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.70 AC KILOVOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 17 STANDOFF,THREADED STUD |