Thank you for choosing to partner with National Stock Number Shop for the Transformer Power NSN parts you require. On this page, you can submit a quote request for General Dynamics Satcom part number CTR015, a component that can also be found by inputting NSN 6120014699388 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 1GD22 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find General Dynamics Satcom parts under the FSC 6120 Transformers Distribution and Power Station with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 6120014699388 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6120-01-469-9388 Item PartTypeName: TRANSFORMER,POWER | 6120 | 014699388 | N | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
CTR015 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABTB | Mounting Hole Diameter | 0.250 INCHES NOMINAL SINGLE GROUP |
CWJS | Winding Operating Voltage | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CBBL | Features Provided | COLOR CODED LEAD AND PROTECTIVE COVER AND SPECIAL MARKING |
ADAU | Body Height | 1.900 INCHES NOMINAL |
ACZB | Frequency Rating | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
CRBZ | Winding Operating Current | 0.6 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | Terminal Type And Quantity | 4 WIRE LEAD |
CRBZ | Winding Operating Current | 0.7 AMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 1.4 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
ACZF | Maximum Transformer Power Rating | 150.0 VOLT-AMPERE SINGLE COMPONENT |
AXGY | Mounting Method | UNTHREADED HOLE SINGLE GROUP |
FEAT | Special Features | SUPPLY VOLTAGE RANGE IS PLUS OR MINUS 10 PERCENT; PRIMARIES ARE INSIDE SLEEVE AND MUST BE CONNECTED TOGETHER IN SERIES OR PARALLEL; PRIMARY LEAD WIRES ARE MAGNET WIRE SELF-LEADS, 24 GAUGE, 8.000 IN. LENGTH NOMINAL; SECONDARY LEAD WIRES ARE MULTI-STRANDED, 22 GAUGE, 8.000 IN. LENGTH NOMINAL; CORE NO. 900140, NO-LOAD LOSS EQUALS 0.9 WATT , NO-LOAD AMPERAGE EQUALS 8.7 MILLIAMPS; UL RECOGNIZED TO UL 1411 AND CSA CERTIFIED TO CSA C22.2, NO. 66 |
ADAR | Body Outside Diameter | 3.900 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
AEHZ | Maximum Operating Temp | 65.0 DEG CELSIUS |
CWJS | Winding Operating Voltage | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
AARG | Reliability Indicator | NOT ESTABLISHED |
AKNA | Inclosure Type | FULLY INCLOSED |