Thank you for choosing to partner with National Stock Number Shop for the Transformer Power NSN parts you require. On this page, you can submit a quote request for Dla Land And Maritime part number 612-4-32208, a component that can also be found by inputting NSN 5950013299515 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 16236 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Dla Land And Maritime parts under the FSC 5950 Coils and Transformers with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 5950013299515 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-329-9515 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013299515 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
612-4-32208 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 90.5 MILLIMETERS MAXIMUM |
ABKW | OVERALL HEIGHT | 112.2 MILLIMETERS MAXIMUM |
CRMJ | WINDING POWER RATING | 2.5 WATTS SINGLE COMPONENT ALL PRIMARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 63.1 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 250.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 66.9 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 88.9 MILLIMETERS MAXIMUM |
ACZB | FREQUENCY RATING | 45.0 HERTZ MINIMUM SINGLE COMPONENT AND 65.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT ALL PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 17 TURRET |