Thank you for choosing to partner with National Stock Number Shop for the Reactor NSN parts you require. On this page, you can submit a quote request for Ail Systems Inc part number 400886, a component that can also be found by inputting NSN 5950009622851 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 04660 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Ail Systems Inc parts under the FSC 5950 Coils and Transformers with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 5950009622851 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-962-2851 Item PartTypeName: REACTOR | 5950 | 009622851 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
400886 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ACYV | INDUCTANCE RATING | 9.00 MILLIHENRIES MAXIMUM SINGLE COMPONENT 2ND WINDING |
AKDX | WINDING QUANTITY | 4 SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT 1ST WINDING |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT 2ND WINDING |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT 3RD WINDING |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT 4TH WINDING |
CRBZ | WINDING OPERATING CURRENT | 1.5 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH WINDING |
CRBZ | WINDING OPERATING CURRENT | 10.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST WINDING |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND WINDING |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.025 SINGLE COMPONENT 1ST WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.025 SINGLE COMPONENT 2ND WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.100 SINGLE COMPONENT 3RD WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.100 SINGLE COMPONENT 4TH WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 8 SOLDER STUD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 4.500 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 4.750 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 4.000 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.203 INCHES NOMINAL SINGLE GROUP |
ACYF | INDUCTANCE TYPE | FIXED |
ACYV | INDUCTANCE RATING | 12.00 MILLIHENRIES MAXIMUM SINGLE COMPONENT 3RD WINDING |
ACYV | INDUCTANCE RATING | 3.00 MILLIHENRIES MAXIMUM SINGLE COMPONENT 1ST WINDING |
ACYV | INDUCTANCE RATING | 36.00 MILLIHENRIES MAXIMUM SINGLE COMPONENT 4TH WINDING |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote