Thank you for choosing to partner with National Stock Number Shop for the Test Stand Hydrauli NSN parts you require. On this page, you can submit a quote request for Aai Corporation part number 9780-0032D, a component that can also be found by inputting NSN 4920013717871 in our search engine. Apart from this item, we also have an array of other in-demand part numbers, all of which can be traced back to a conglomerate of well-known manufacturers that we trust. Explore our expansive part catalogs by scrolling over to our menu and locate products according to manufacturer, NIIN, NSN, and more.
National Stock Number Shop works with numerous government and defense agencies, so we use CAGE Codes like 05172 to uniquely identify items in a standardized manner. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Aai Corporation parts under the FSC 4920 Aircraft Maintenance And Repair Shop Specialized Equipment with ease. With this in mind, we encourage you to complete the RFQ form below for NSN 4920013717871 or any others, and see how we can provide you with a customized sourcing solution. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock for customer inquiries!
Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
SUPP | Supplementary Features | TRAILER MOUNTED CABINET WITH 4 APPX 10 INCH WHEELS |
CHGQ | Filtering System | INCLUDED |
RDAL | Reference Data And Literature | SERD NO. 1328 |
BGST | Pressure Rating | 3100.0 POUNDS PER SQUARE INCH NOMINAL |
RTSE | Relationship To Similar Equipment | 4920-00-104-7838 |
FEAT | Special Features | INSTRUMENTATION INCLUDES PRESSURE,FLOW,AND TEMPERATURE DISPLAY; HEAT EXCHANGER,DIESEL ENGINE (100 HP,2300 RPM),FUEL TANK-40 GALLON,RESERVIOR-55 GALLON,FLOWMETER,FILTRATION 3 MICRON ABSOLUTE |
FCLS | Functional Classification | GG-8.4 |
FTLD | Functional Description | DESIGNED TO PROVIDE A SOURCE OF HYD POWER UP TO 50 GPM AT 3100 PSIG WITH OPEN OR CLOSED LOOP OPERATION. USED TO OPERATE ACFT HYD SYS (SKYFROL) W/O RUNNING ENGINE PUMPS TO TEST THE LANDING GEAR AND CONTROL SYS; USED ALSO TO DRAIN,FLUSH,FILL,OR DEAERATE THE HYD SYSTEM |
AAYJ | Hydraulic Fluid Flow Rate | 50.0 GALLONS PER MINUTE |
ALBY | Usage Design | AIRCRAFT HYDRAULIC SYSTEM |
MRC | Decoded Requirement | Clear Text Reply |
AMQY | Installation Design | PORTABLE |
ZZZV | Fsc Application Data | E-8A ACFT AGE. |