If your operations demand dependable items that fall under the NSN 6625-01-172-9390, look no further than the expansive product list featured on this page. For your convenience, all NSN 6625-01-172-9390 part numbers that we have in stock like 83540A-002, and others are listed below with their respective manufacturer. Should any of these products match your requirements, you may click on the “RFQ” button presented next to each listing to access our online quote request service. By providing our team with information like your desired part quantity, pricing, and fulfillment speed on the form you are directed to, we can offer a procurement solution that best accommodates your needs within 15 minutes of our receipt and review.
You never have to compromise any of your needs when you shop with us, as we always aim to offer competitive pricing and delivery times for every order. Furthermore, quality is a fundamental cornerstone of our operations, and we carry out various practices to guarantee the fit, form, and function of our NSN 6625-01-172-9390 products, starting with strictly sourcing from trustworthy NSN parts suppliers and manufacturers. To learn more about our diverse commitments and see why so many customers steadily depend on our services, connect with us by form, phone, or email at your earliest convenience.
Item Name | Generator Sweep |
Federal Supply Group (FSG) | Instruments and Laboratory Equipment |
Federal Supply Class (FSC) | 6625 Electrical and Electronic Properties Measuring and Testing Instruments |
National Item Identification Number (NIIN) | 01-172-9390 (011729390) |
NCB Code | USA (01) |
Manufacturer | Keysight Technologies Inc, Hewlett-Packard Company |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
83540A-002 | keysight technologies inc | generator sweep | RFQ |
83540A-002 | hewlett-packard company | generator sweep | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
BHTJ | AVERAGE POWER RATING PER CHANNEL | 32.0 MILLIWATTS OUTPUT |
BHTW | PULSE PEAK AMPLITUDE PER CHANNEL | NOT RATED |
AMQY | INSTALLATION DESIGN | MODULE |
BJBM | MAXIMUM CONTINUOUS OPERATING TIME IN HOURS | NOT RATED |
BJBP | CONNECTION TYPE AND LOCATION | RECEPTACLE, COAXIAL FRONT |
SR-5 | MANUFACTURERS CODE | 1LQK8 |
FEAT | SPECIAL FEATURES | CONTAINS 70 DECIBEL STEP ATTENUATOR |
SR-5 | DESIGN CONTROL REFERENCE | 83540A-002 |
AKNA | INCLOSURE TYPE | ENCASED |
SR-5 | THE MANUFACTURERS DATA | |
AFDP | SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS | NOT RATED |
AFGA | OPERATING TEMP RANGE | NOT RATED |
AFSU | AVERAGE LIFE MEASUREMENT | NOT RATED |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | NOT RATED |
BHTL | OVERALL GAIN | NOT RATED |
BJBW | CONNECTION CONTACT TYPE AND QUANTITY | 2 RECEPTACLE, COAXIAL EXTERNAL |
AJKH | IDENTIFICATION DESIGNATOR | 83540A-002-28480 |
BHTB | FREQUENCY PER CHANNEL | 2.0 GIGAHERTZ MINIMUM OUTPUT CHANNEL AND 8.4 GIGAHERTZ MAXIMUM OUTPUT CHANNEL |
BHTZ | SIGNAL DATA TYPE PER CHANNEL | OUTPUT CHANNEL RADIO FREQUENCY OUTPUT CHANNEL SWEEP |
BHSX | CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
AGTA | BASIC SHAPE STYLE | RECTANGULAR OR SQUARE |
BHTD | FREQUENCY ADJUSTMENT TYPE | CONTINUOUS |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | NOT RATED |
BHTH | ATTENUATION IN DECIBELS | 70.0 |
BHTK | SIGNAL VOLTAGE RATING PER CHANNEL | NOT RATED |
BHTN | IMPEDANCE RATING PER CHANNEL | 50.000 OHMS OUTPUT CHANNEL |
Relevant Components for NSN - 6625-01-172-9390, 6625011729390 | ||||
6625-00-966-0594 (6625009660594) | 6640-01-415-4515 (6640014154515) | 6625-00-173-7076 (6625001737076) | 6625-01-521-7873 (6625015217873) | |
6640-01-643-7269 (6640016437269) | 6625-01-120-1142 (6625011201142) | 6625-00-184-8474 (6625001848474) | 6660-01-551-2666 (6660015512666) | |
6640-00-414-3000 (6640004143000) | 6625-01-026-6013 (6625010266013) | 6680-00-303-9665 (6680003039665) | 6625-00-244-3067 (6625002443067) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote