If your operations demand dependable items that fall under the NSN 6145-01-407-1696, look no further than the expansive product list featured on this page. For your convenience, all NSN 6145-01-407-1696 part numbers that we have in stock like 80216, and others are listed below with their respective manufacturer. Should any of these products match your requirements, you may click on the “RFQ” button presented next to each listing to access our online quote request service. By providing our team with information like your desired part quantity, pricing, and fulfillment speed on the form you are directed to, we can offer a procurement solution that best accommodates your needs within 15 minutes of our receipt and review.
You never have to compromise any of your needs when you shop with us, as we always aim to offer competitive pricing and delivery times for every order. Furthermore, quality is a fundamental cornerstone of our operations, and we carry out various practices to guarantee the fit, form, and function of our NSN 6145-01-407-1696 products, starting with strictly sourcing from trustworthy NSN parts suppliers and manufacturers. To learn more about our diverse commitments and see why so many customers steadily depend on our services, connect with us by form, phone, or email at your earliest convenience.
Item Name | Cable Specificationial Purpose Electrical |
Federal Supply Group (FSG) | Electric Wire and Power and Distribution Equipment |
Federal Supply Class (FSC) | 6145 Wire and Cable Electrical |
National Item Identification Number (NIIN) | 01-407-1696 (014071696) |
NCB Code | USA (01) |
Manufacturer | South Bay Cable Corp |
MRC | Criteria | Characteristic |
---|---|---|
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 4TH POSITION TAPE ALL GROUPS |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
MATT | Material | PLASTIC POLYURETHANE 6TH POSITION JACKET CABLE |
MATT | Material | COPPER 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN 3RD POSITION SHIELD BRAID, METALLIC THIRD GROUP |
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
MATT | Material | COPPER 5TH POSITION SHIELD BRAID, METALLIC THIRD GROUP |
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 3RD POSITION TAPE SECOND CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 7TH CONDUCTOR |
AMQN | Conductor Quantity | 9 |
HUES | Color | BROWN 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 6TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 8TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 5TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 2ND CONDUCTOR |
HUES | Color | GREEN 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 3RD CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 9TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 4TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 1ST CONDUCTOR |
HUES | Color | ORANGE 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
HUES | Color | BLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
AAGR | Cross-Sectional Shape Style | ROUND |
CXDC | Round Conductor Size | 16 AWG 4TH CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 5TH CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 9TH CONDUCTOR |
HUES | Color | GREEN 1ST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR |
CXDC | Round Conductor Size | 22 AWG 1ST CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 7TH CONDUCTOR |
MRC | Decoded Requirement | Clear Text Reply |
CXDG | Strand Awg Size Per Conductor | 26 9TH CONDUCTOR |
ABJH | Temp Rating | -28.0 DEG CELSIUS AND 65.0 DEG CELSIUS |
CXDG | Strand Awg Size Per Conductor | 29 5TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 26 7TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 3RD CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 3RD CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 6TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 30 1ST CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 6TH CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 8TH CONDUCTOR |
CXDT | Group Quantity | 4 |
MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXFG | Conductor Sequence Within Groups | FIRST CONDUCTOR FIRST GROUP AND SECOND CONDUCTOR FIRST GROUP |
CXFG | Conductor Sequence Within Groups | SEVENTH CONDUCTOR FOURTH GROUP AND EIGHTH CONDUCTOR FOURTH GROUP AND NINTH CONDUCTOR FOURTH GROUP |
CXDC | Round Conductor Size | 22 AWG 2ND CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 26 8TH CONDUCTOR |
MATT | Material | COPPER 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR |
HUES | Color | RED 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 4TH CONDUCTOR |
SFTT | Surface Treatment | TIN 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR |
HUES | Color | WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN CORE CONDUCTOR ALL CONDUCTORS |
CXDG | Strand Awg Size Per Conductor | 30 2ND CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 3RD POSITION TAPE FIRST CONDUCTOR |
HUES | Color | YELLOW 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR |
HUES | Color | YELLOW 1ST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
CXDQ | Conductor Arrangement And Quantity | 2 SINGLES AND 2 TWISTED PAIR AND 1 TRIPLES |
CXFG | Conductor Sequence Within Groups | FIFTH CONDUCTOR THIRD GROUP AND SIXTH CONDUCTOR THIRD GROUP |
CXFG | Conductor Sequence Within Groups | THIRD CONDUCTOR SECOND GROUP AND FOURTH CONDUCTOR SECOND GROUP |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
ADVL | Cross Section Outside Diameter | 0.665 INCHES NOMINAL |
Relevant Components for NSN - 6145-01-407-1696, 6145014071696 | ||||
6150-01-593-8572 (6150015938572) | 6145-01-066-4947 (6145010664947) | 6145-01-543-4719 (6145015434719) | 6110-01-575-1365 (6110015751365) | |
6130-01-138-1685 (6130011381685) | 6145-00-815-4954 (6145008154954) | 6150-01-443-6397 (6150014436397) | 6130-01-645-8568 (6130016458568) | |
6130-01-172-6978 (6130011726978) | 6150-01-072-2081 (6150010722081) | 6150-99-797-0492 (6150997970492) | 6150-01-152-6236 (6150011526236) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote