If your operations demand dependable items that fall under the NSN 5985-00-729-2496, look no further than the expansive product list featured on this page. For your convenience, all NSN 5985-00-729-2496 part numbers that we have in stock like 9185484, A12811, and others are listed below with their respective manufacturer. Should any of these products match your requirements, you may click on the “RFQ” button presented next to each listing to access our online quote request service. By providing our team with information like your desired part quantity, pricing, and fulfillment speed on the form you are directed to, we can offer a procurement solution that best accommodates your needs within 15 minutes of our receipt and review.
You never have to compromise any of your needs when you shop with us, as we always aim to offer competitive pricing and delivery times for every order. Furthermore, quality is a fundamental cornerstone of our operations, and we carry out various practices to guarantee the fit, form, and function of our NSN 5985-00-729-2496 products, starting with strictly sourcing from trustworthy NSN parts suppliers and manufacturers. To learn more about our diverse commitments and see why so many customers steadily depend on our services, connect with us by form, phone, or email at your earliest convenience.
Item Name | Waveguide Assembly |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5985 Antennas Waveguides and Related Equipment |
National Item Identification Number (NIIN) | 00-729-2496 (007292496) |
NCB Code | USA (00) |
Manufacturer | Arra Inc, Omega Laboratories Inc, Autodyne Manufacturing Co Inc |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AAJD | THREAD CLASS | 2B FIRST FLANGE ALL CONNECTION FACILITIES |
AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.896 INCHES MINIMUM FIRST FLANGE AND 0.904 INCHES MAXIMUM FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 1.003 INCHES MINIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.503 INCHES MINIMUM SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 1.406 INCHES MINIMUM FIRST FLANGE AND 1.437 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM FIRST FLANGE AND 0.453 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
CMLP | THREAD QUANTITY PER INCH | 32 FIRST FLANGE ALL CONNECTION FACILITIES |
CQGM | MAXIMUM OPERATING PRESSURE | 15.0 POUNDS PER SQUARE INCH GAGE |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
CXBB | WAVEGUIDE CENTER TO CENTER DISTANCE | 1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY 6061 ALL TUBING SEGMENT AND FLANGE |
SFTT | SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
STYL | STYLE DESIGNATOR | DOUBLE BEND TYPE |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE ALL CONNECTION FACILITIES |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
AHSY | FLANGE INSIDE HEIGHT | 0.396 INCHES MINIMUM FIRST FLANGE AND 0.404 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM |
CXBD | WAVEGUIDE HEIGHT | 1.495 INCHES MINIMUM AND 1.505 INCHES MAXIMUM |
Relevant Components for NSN - 5985-00-729-2496, 5985007292496 | ||||
5990-00-676-9434 (5990006769434) | 5999-01-413-7247 (5999014137247) | 5935-01-541-9509 (5935015419509) | 5935-01-484-0560 (5935014840560) | |
5962-01-565-1699 (5962015651699) | 5998-01-089-5401 (5998010895401) | 5940-00-476-0184 (5940004760184) | 5999-01-606-7533 (5999016067533) | |
5999-01-646-2820 (5999016462820) | 5905-01-256-9336 (5905012569336) | 5962-01-236-5840 (5962012365840) | 5950-01-062-7415 (5950010627415) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.