If your operations demand dependable items that fall under the NSN 5950-01-302-3330, look no further than the expansive product list featured on this page. For your convenience, all NSN 5950-01-302-3330 part numbers that we have in stock like 593R819A01, and others are listed below with their respective manufacturer. Should any of these products match your requirements, you may click on the “RFQ” button presented next to each listing to access our online quote request service. By providing our team with information like your desired part quantity, pricing, and fulfillment speed on the form you are directed to, we can offer a procurement solution that best accommodates your needs within 15 minutes of our receipt and review.
You never have to compromise any of your needs when you shop with us, as we always aim to offer competitive pricing and delivery times for every order. Furthermore, quality is a fundamental cornerstone of our operations, and we carry out various practices to guarantee the fit, form, and function of our NSN 5950-01-302-3330 products, starting with strictly sourcing from trustworthy NSN parts suppliers and manufacturers. To learn more about our diverse commitments and see why so many customers steadily depend on our services, connect with us by form, phone, or email at your earliest convenience.
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 01-302-3330 (013023330) |
NCB Code | USA (01) |
Manufacturer | Northrop Grumman Systems Corporation |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
593R819A01 | northrop grumman systems corporation | transformer power | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.940 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.790 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.147 INCHES NOMINAL 2ND GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.191 INCHES NOMINAL 1ST GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA AND DELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.570 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.320 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.980 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 70.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | F-16 ADF RADAR |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 3 2ND GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 1ST GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CQKH | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE BASE OF AN ISOSCELES TRIANGLE | 1.570 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 245.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 270.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 91.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 0.350 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 1.19 AC KILOVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 123.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.33 AC KILOVOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
TEST | TEST DATA DOCUMENT | 97942-593R819 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 24 TURRET |
Relevant Components for NSN - 5950-01-302-3330, 5950013023330 | ||||
5998-01-050-1783 (5998010501783) | 5998-01-024-1597 (5998010241597) | 5995-01-587-3795 (5995015873795) | 5998-01-039-5005 (5998010395005) | |
5910-01-262-1769 (5910012621769) | 5962-00-370-0419 (5962003700419) | 5930-00-860-1512 (5930008601512) | 5995-01-074-6960 (5995010746960) | |
5930-01-284-4129 (5930012844129) | 5915-01-102-6515 (5915011026515) | 5998-01-278-2208 (5998012782208) | 5950-00-492-1885 (5950004921885) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote