If your operations demand dependable items that fall under the NSN 5925-01-394-7248, look no further than the expansive product list featured on this page. For your convenience, all NSN 5925-01-394-7248 part numbers that we have in stock like AP112-1R-24245-4, 1211696-201, and others are listed below with their respective manufacturer. Should any of these products match your requirements, you may click on the “RFQ” button presented next to each listing to access our online quote request service. By providing our team with information like your desired part quantity, pricing, and fulfillment speed on the form you are directed to, we can offer a procurement solution that best accommodates your needs within 15 minutes of our receipt and review.
You never have to compromise any of your needs when you shop with us, as we always aim to offer competitive pricing and delivery times for every order. Furthermore, quality is a fundamental cornerstone of our operations, and we carry out various practices to guarantee the fit, form, and function of our NSN 5925-01-394-7248 products, starting with strictly sourcing from trustworthy NSN parts suppliers and manufacturers. To learn more about our diverse commitments and see why so many customers steadily depend on our services, connect with us by form, phone, or email at your earliest convenience.
| Item Name | Circuit Breaker |
| Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
| Federal Supply Class (FSC) | 5925 Circuit Breakers |
| National Item Identification Number (NIIN) | 01-394-7248 (013947248) |
| NCB Code | USA (01) |
| Manufacturer | Sensata Technologies Inc, Lockheed Martin Corporation |
| Part Number | Manufacturer | Item Name | RFQ |
|---|---|---|---|
| AP112-1R-24245-4 | sensata technologies inc | circuit breaker | RFQ |
| 1211696-201 | lockheed martin corporation | circuit breaker | RFQ |
| MRC | Criteria | Characteristic |
|---|---|---|
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 THREADED HOLE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 80.0 AMPERES AC THIRD LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 ALL LOCATIONS |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| ADAT | BODY WIDTH | 3.040 INCHES NOMINAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
| AJEC | BOSS HEIGHT | 0.138 INCHES NOMINAL |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.700 MINIMUM AT 200 PCT AND 10.100 MAXIMUM AT 200 PCT FIRST LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.700 MINIMUM AT 200 PCT AND 10.100 MAXIMUM AT 200 PCT SECOND LOCATION |
| ADAQ | BODY LENGTH | 2.500 INCHES MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.060 INCHES NOMINAL |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP FOURTH LOCATION |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SECOND LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.700 MINIMUM AT 200 PCT AND 10.100 MAXIMUM AT 200 PCT THIRD LOCATION |
| CWJK | CASE MATERIAL | PLASTIC |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.675 INCHES NOMINAL |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.625 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 4 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC FOURTH LOCATION |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 80.0 AMPERES AC FIRST LOCATION |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 80.0 AMPERES AC SECOND LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 4 TOGGLE |
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIRST LOCATION |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP THIRD LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.015 MAXIMUM AT 200 PCT FOURTH LOCATION |
| THSD | THREAD SERIES DESIGNATOR | UNC |
| TTQY | TERMINAL TYPE AND QUANTITY | 10 THREADED STUD |
| Relevant Components for NSN - 5925-01-394-7248, 5925013947248 | ||||
| 5998-01-422-0010 (5998014220010) | 5935-01-050-7065 (5935010507065) | 5961-01-071-3238 (5961010713238) | 5910-01-293-3829 (5910012933829) | |
| 5998-01-365-8263 (5998013658263) | 5905-00-492-9572 (5905004929572) | 5977-01-415-4856 (5977014154856) | 5961-00-938-3499 (5961009383499) | |
| 5975-01-590-0822 (5975015900822) | 5905-01-341-8896 (5905013418896) | 5995-01-554-4292 (5995015544292) | 5975-01-693-3048 (5975016933048) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote