| MRC | Criteria | Characteristic | 
|---|
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION | 
| AHCG | MAXIMUM TEMP RISE | 40.0 DEG CELSIUS | 
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 1ST RADIO INTERFERENCE AND 400.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION | 
| ABHP | OVERALL LENGTH | 20.000 INCHES NOMINAL | 
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.187 INCHES NOMINAL | 
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 14.750 INCHES NOMINAL | 
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 600.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION | 
| AHAS | LOAD IMPEDANCE PER FUNCTION | 600.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION | 
| AHCJ | FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.014 AND 10000.0 | 
| AFGA | OPERATING TEMP RANGE | -55.0 TO 65.0 DEG CELSIUS | 
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 600.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION | 
| AHAS | LOAD IMPEDANCE PER FUNCTION | 600.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION | 
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 1ST RADIO INTERFERENCE 1ST FUNCTION | 
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 2ND RADIO INTERFERENCE AND 400.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION | 
| ADAQ | BODY LENGTH | 20.000 INCHES NOMINAL | 
| ADAT | BODY WIDTH | 12.000 INCHES NOMINAL | 
| ADAU | BODY HEIGHT | 6.000 INCHES NOMINAL | 
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 600.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION | 
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 600.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION | 
| AHAS | LOAD IMPEDANCE PER FUNCTION | 600.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION | 
| AHAS | LOAD IMPEDANCE PER FUNCTION | 600.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION | 
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE 1ST FUNCTION | 
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 3RD RADIO INTERFERENCE 3RD FUNCTION | 
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 4TH RADIO INTERFERENCE 4TH FUNCTION | 
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 2ND RADIO INTERFERENCE 2ND FUNCTION | 
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 3RD RADIO INTERFERENCE 3RD FUNCTION | 
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 4TH RADIO INTERFERENCE 4TH FUNCTION | 
| AKNA | INCLOSURE TYPE | ENCASED | 
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE | 
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 THREADED STUD INPUT 1ST FUNCTION | 
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 THREADED STUD OUTPUT 2ND FUNCTION | 
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 3RD RADIO INTERFERENCE AND 400.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION | 
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 4TH RADIO INTERFERENCE AND 400.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION | 
| CQRG | BODY MATERIAL | METAL | 
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 1250.0 VOLTS AT ALTITUDE | 
| CRST | BODY SURFACE TREATMENT | TIN | 
| CTJS | UNPACKAGED UNIT WEIGHT | 40.000 POUNDS NOMINAL | 
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |