| MRC | Criteria | Characteristic |
|---|
| ABHP | OVERALL LENGTH | 4.500 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 3.500 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 4.000 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.750 INCHES NOMINAL |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.750 INCHES NOMINAL |
| AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
| AGAV | END ITEM IDENTIFICATION | MISSILE GUIDANCE AND TRACKING SET AN/SPG-55B |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 3RD RADIO INTERFERENCE |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 4TH RADIO INTERFERENCE |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 5TH RADIO INTERFERENCE |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 6TH RADIO INTERFERENCE |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.033 1ST RADIO INTERFERENCE |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.033 2ND RADIO INTERFERENCE |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.033 3RD RADIO INTERFERENCE |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.033 4TH RADIO INTERFERENCE |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.033 5TH RADIO INTERFERENCE |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.033 6TH RADIO INTERFERENCE |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 1ST RADIO INTERFERENCE AND 0.05 VOLTS DC 1ST RADIO INTERFERENCE |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 2ND RADIO INTERFERENCE AND 0.05 VOLTS DC 2ND RADIO INTERFERENCE |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 3RD RADIO INTERFERENCE AND 0.05 VOLTS DC 3RD RADIO INTERFERENCE |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 4TH RADIO INTERFERENCE AND 0.05 VOLTS DC 4TH RADIO INTERFERENCE |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 5TH RADIO INTERFERENCE AND 0.05 VOLTS DC 5TH RADIO INTERFERENCE |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 6TH RADIO INTERFERENCE AND 0.05 VOLTS DC 6TH RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHBN | INPUT TERMINAL MANUFACTURER CODE | 96906 |
| AHBP | INPUT TERMINAL IDENTIFICATION | MS3124E12-10P |
| AHBS | OUTPUT TERMINAL MANUFACTURER CODE | 96906 |
| AHBT | OUTPUT TERMINAL IDENTIFICATION | MS3124E12-10S |
| AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 CONNECTOR,RECEPTACLE OUTPUT 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION AND 5.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION AND 5.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION AND 5.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION AND 5.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION AND 5.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION AND 5.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |
| CQRG | BODY MATERIAL | METAL |
| FEAT | SPECIAL FEATURES | EIGHT FILTERED AND TWO UNFILTERED FUNCTIONS |
| STYL | STYLE DESIGNATOR | FILTER CONNECTOR |