| MRC | Criteria | Characteristic |
|---|
| ABHP | OVERALL LENGTH | 39.000 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 37.000 INCHES NOMINAL |
| ADAT | BODY WIDTH | 20.000 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 5.000 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.688 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 25.000 INCHES NOMINAL |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 22.000 INCHES NOMINAL |
| AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 25.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 25.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 25.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.77 VOLTS AC 1ST RADIO INTERFERENCE AND 6.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.77 VOLTS AC 2ND RADIO INTERFERENCE AND 6.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.77 VOLTS AC 3RD RADIO INTERFERENCE AND 6.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| CBBL | FEATURES PROVIDED | CORROSION RESISTANT |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 TAB,SOLDER LUG INPUT 1ST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 TAB,SOLDER LUG OUTPUT 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 277.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION AND 600.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 277.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION AND 600.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 277.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION AND 600.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| CQRG | BODY MATERIAL | METAL |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 1.2 KILOVOLTS AT SEA LEVEL |
| FEAT | SPECIAL FEATURES | THREE FILTER FUNCTIONS |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |