| MRC | Criteria | Characteristic |
|---|
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 35.3 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 42.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 48.7 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 54.3 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 63.3 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 70.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 78.4 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 86.8 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0/10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| CBME | CUBIC MEASURE | 0.006 CUBIC INCHES |
| CQWD | ZERO POWER RESISTANCE | 56.000 OHMS |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/10.0 |
| STYL | STYLE DESIGNATOR | ROD |
| TEST | TEST DATA DOCUMENT | 13499-714-1135 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 0.406 INCHES NOMINAL |
| ADAR | BODY OUTSIDE DIAMETER | 0.140 INCHES NOMINAL |
| AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
| AEHX | MAXIMUM POWER DISSIPATION RATING | 125.00 MILLIWATTS |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
| AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -25.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -50.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -75.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 130.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 20.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 40.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 60.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 80.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 100.8 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 30.2 OHMS 1ST RESISTANCE-TEMPERATURE POINT |