| MRC | Criteria | Characteristic |
|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL |
| ADAR | BODY OUTSIDE DIAMETER | 0.500 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.200 INCHES NOMINAL |
| AEBT | TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
| AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 25.0 |
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 11.0 |
| AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -3.96 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -20.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -40.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 120.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 140.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 20.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 40.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 60.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 80.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.2 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 112.5 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 180.0 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.9 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 20.4 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 337.5 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 607.5 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 69.8 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 7.0 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 71.6 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.8 TO 10.8 4TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.7 TO 12.7 5TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.3 TO 14.3 6TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.9 TO 15.9 3RD RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.6 TO 16.6 7TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.2 TO 18.2 8TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.3 TO 18.3 2ND RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.7 TO 20.7 9TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -21.7 TO 21.7 1ST RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -22.0 TO 22.0 10TH RESISTANCE-TEMPERATURE POINT |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| CBME | CUBIC MEASURE | 0.006 CUBIC INCHES |
| CQWD | ZERO POWER RESISTANCE | 2.250 KILOHMS |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| SFTT | SURFACE TREATMENT | SOLDER TERMINAL |
| STYL | STYLE DESIGNATOR | DISK |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |